Panendoscopy Room Setup
EQUIPMENT
- Operating room table in reverse orientation with arm boards
- Audio-video unit (for telescope)
- Telescope camera
- Fiberoptic luminator (scope compatible light source)
- Double shelf table (place light sources under setup)
- Gown table
- Mayo stand
- Fiberoptic light projector with headlight x 2
- Plexiglass suspension frame
- Unipolar cautery unit
- Suction bottle stand x 2
- IV stand x 2
- Elbow guards x 2
- Pillows x 2
- Foam padding
- Reliance hydraulic stool with back
- Clark socket for suspension
SUPPLIES FOR STERILE FIELD
- Panendoscopy Pack
- Telfa for specimens
- Gump to protect teeth
- K-Y jelly
- Fog-out for telescope or hot water
- Neurosurgical cottonoids 1/2 x 1/2, 1/2 x 3 (have available if biopsies or manipulation of vocal cords occur)
- 5ml syringe
- 14G abbocath/25G hypodermic needle
- Irrigation basin
- Towels and pillowcases
DRUGS TO HAVE ON THE FIELD
- 4% Lidocaine
- nasal spray
- saline
Special Setup Note
In the majority of these cases, the surgical bed is turned 90° away from anesthesia.